Opened 5 years ago

Closed 5 years ago

#242 closed defect - wrong answer (fixed)

large H2 model has strong effect on CO abundance in 1e4K coronal model

Reported by: Gary J. Ferland Owned by: nobody
Priority: critical Milestone: c13 release
Component: etc Version: trunk
Keywords: Cc:

Description

sim with no H2 has little CO, while with atom H2 most C is in CO at r6822

Attachments (1)

Archive.zip (59.9 KB) - added by Gary J. Ferland 5 years ago.
input, output, and overview, for sim with/without atom H2

Download all attachments as: .zip

Change History (3)

Changed 5 years ago by Gary J. Ferland

Attachment: Archive.zip added

input, output, and overview, for sim with/without atom H2

comment:1 Changed 5 years ago by Gary J. Ferland

Milestone: c13 release

comment:2 Changed 5 years ago by Ryan Porter

Resolution: fixed
Status: newclosed

Fixed in r6825.